A1. A2. A3. A4. A5. REVIEW NUMBER 5 ANSWERS TO QUESTIONS Q1. THROUGH Q5. The three HERO ordnance classifications are HERO safe, HERO susceptible, and HERO unsafe. HERO-safe ordnance must be percussion initiated and shielded enough so that EDDs are safe when used in RF environments. HERO-susceptible and HERO-unsafe ordnance should not be exposed to RF environments. The HERO EMCON Bill contains a degree of relief from HERO RF restrictions. The HERO EMCON Bill contains a list of all HERO-susceptible and HERO-unsafe ordnance items on board the command. 11-34