10-32.
What is the proper procedure to
follow if a panel-mounted
regulator fails the oxygen ratio
test?
1.
Dispose of it according to
local directives
2.
Perform an aneroid closure
test
3.
Perform an emergency
pressure test
4.
Replace the venturi assembly
10-33.
When you perform the aneroid
closure test, the aneroid should
close within what range?
1.
22,000 and 25,000 feet
2.
25,000 and 28,000 feet
3.
28,000 and 32,000 feet
4.
32,000 and 43,000 feet
1034.
The blinker assembly test
ensures that the blinker
operates correctly with a demand
placed on the regulator.
When a
flow of 12 lpm is drawn through
the regulator, with 17.0 inches
of H2O indicated on the
pressure/suction manometer, the
blinker should be in what
position?
1.
Fully closed
2.
Half closed
3.
One quarter open
4.
Fully open
1. 50
2. 60
3. 75
4. 110
Learning Objective:
Identify,
maintain, and perform mainte-
nance on liquid oxygen
converters.
10-35.
Liquid oxygen (LOX) is stored at
approximately what temperature?
1. 110
2. 115
3. 125
4. 130
1. -282°F
2. -297°F
3. -282°C
4. -297°F
10-36.
The quantity gauge used on a LOX
converter indicates the amount
of LOX in what units?
1.
Pounds
2.
Gallons
3.
Liters
4.
Kilos
10-37.
When you fill a LOX converter
with the use of a servicing
trailer, the converter is
considered full when what
condition exists?
1.
The servicing trailer
quantity gauge indicates
full
2.
The converter capacitance
probe indicates full
3.
The servicing trailer stops
delivering LOX
4.
A steady stream of LOX flows
from the overboard vent
10-38.
At what approximate pressure
does the LOX converter pressure
closing valve function?
1.
60 psig
2.
75 psig
3.
100 psig
4.
110 psig
10-39.
A relief valve is incorporated
into LOX systems to prevent
excessive pressure buildup. On
most LOX systems this relief
valve is set to open at
approximately how many psig?
10-40.
Additional protection against
over pressurization of a LOX
converter installed in an
aircraft is a relief valve
installed in the aircraft oxygen
plumbing.
This relief valve is
set at approximately how many
psig?
10-41.
When performing the relief valve
test, a pressure of 100 to 120
psig is applied to the relief
valve.
The relief valve should
vent a minimum of how many
liters per minute?
1.
50
2.
100
3.
150
4.
200
57