no power is supplied to the aircraft. The RESET
position resets power for the external monitoring circuit
when there is a temporary overload. Switch 1 is a
three-position switch with B ON to provide enabling
power to the mission computers.
Switch 2 is a
three-position switch with B ON to provide enabling
power to the digital display indicators (DDIs). The B
ON switch also enables power to the aircraft radar.
Switch 3 is a three-position switch with B ON to
provide enabling power to the armament computer
stores management panel (SMP), AN/AWW-4 system,
HARM system, and the AN/ALE-39 system.
15-11
MULTIPURPOSE
PYLON
LAU-93
ADAPTER
LAU-93/LAU-132
LAUNCHER
(2 PYLON STATIONS)
WEAPONS
RAIL
LAU-93/LAU-132
LAUNCHER
(4 WEAPONS RAIL STATIONS)
AOf1508
Figure 15-8.LAU-93/LAU-132 configuration on aircraft.