(without refrigeration of ambient temperatures)
The A/M32C-17 air conditioner is designed to
throughout the ambient temperature range.
operate at an ambient temperature range from 0F to
110F dry bulb and 85F wet bulb. It is capable of being
The unit operates as a refrigeration system,
stored at -65F without adverse effect.
delivering air temperature at 45F 5 with a maximum
relative humidity of 80 percent with no entrained water
The unit can operate at pressure altitudes from sea
at the coupling end of the delivery hose. The unit is
level to 5,000 feet. It is capable of delivering 150
pounds per minute of refrigerated air, ventilating air, or
temperatures ranging from 40F to 110F dry bulb and
hot dehumidified air at static pressures up to 2 psi 30
85F wet bulb. Delivery air is supplied at a temperature
feet from an 8-inch diameter insulated flexible duct. It
of at least 90F. The dew point of the delivery air will
can also deliver 75 pounds per minute of air at static
not exceed 40F throughout the ambient temperature
pressures up to 4 psi at the end of the delivery hose. The
range from 40F to 110F dry bulb or 85F wet bulb.
unit is capable of operating as a ventilating blower
2
3
1
17
EMERGENCY
STOP
4
AIR TEMPERATURE
AIR PRESSURE
5
CLUTCH ENGAGED
DISCHARGE
6
SUCTION
PUMP DOWN
15
AIR CONDITION
START VENTILATE
DEHUMIDIFY
OFF
PANEL LIGHTS
LOW FUEL
7
8
16
9
+
14
START
THROTTLE
SHUT OFF
11
13
ASf11020
10
12
10.
STARTER SWITCH
1.
OUTLET AIR TEMPERATURE GAUGE
11.
ENGINE SPEED THROTTLE
2.
CLUTCH INDICATOR LIGHT
12.
3.
OUTLET AIR PRESSURE GAUGE
13.
FUEL SHUTOFF
4.
14.
ENGINE OIL PRESSURE GAUGE
5.
15.
6.
PANEL LIGHT SWITCH
16.
SELECTOR SWITCH
7.
FUEL LEVEL GAUGE (LARGE TANK)
17.
EMERGENCY STOP (NOT ON UNITS WITH HKQ
8.
FUEL WARNING LIGHT
SERIAL NUMBERS)
9.
ENGINE COOLANT TEMPERATURE GAUGE
Figure 11-20.--A/M32C-17 control panel.
11-20