3-44.
When the eductor causes a decrease
in fuel pressure on top of the
diaphragm of the shutoff valve, how
will the shutoff valve be affected?
1.
The filter discharge pressure
will open the valve
2.
The filter discharge pressure
will close the valve
3.
The tension spring will close
the valve
4.
The increase in filter
discharge pressure applied to
the top of the diaphragm will
open the valve
3-45.
What causes the automatic shutoff
valve to close when the pilot valve
closes?
1.
Fuel pressure acting on the
bottom of the diaphragm in the
automatic shutoff valve
2.
Fuel pressure being directed
through the eductor suction
line to the top of the cover
chamber of the automatic
shutoff valve
3.
Fuel pressure being directed to
the top of the diaphragm in the
automatic water drain valve
4.
Fuel pressure being directed to
the bottom of the diaphragm in
the automatic water drain valve
3-46.
What are the operating positions of
the rotary control valve?
1.
Down and up only
2.
Down and horizontal only
3.
Horizontal and up only
4.
Down, horizontal, and up
3-47.
What valve directs filter pressure
through its ports to the tops of
the diaphragms of the pilot and
automatic water drain valves?
3-48.
When there is little to no water
passing through the fuel filter and
the ball float is in the DOWN
position, the rotary control valve
directs filter pressure to. and
vents it to, which valves?
1.
Directs to the top of the water
drain valve and vents the top
of the pilot valve
2.
Directs to the bottom of the
water drain valve and vents the
top of the pilot valve
3.
Directs to the top of the water
drain valve and vents the
bottom of the water drain valve
4.
Directs to the top of the
automatic shutoff valve and
vents the top of the water
drain valve
3-49.
When all valves of the filter
hydraulic system are open and
coalesced water is draining from
the sump, in what position will the
ball float be?
1.
Down
2.
Vertical
3.
Horizontal
4.
Up
3-50.
Under which of the following
conditions will the pilot and
automatic shutoff valves be closed?
1.
The float is in the DOWN
position with no water drainage
required
2.
The float is in the HORIZONTAL
position and the accumulated
water is draining
3.
The float is in the UP position
and the accumulated water is
not draining fast enough
4.
During normal operations
1.
The pilot valve
2.
The automatic shutoff valve
3.
The rotary control valve
4.
The automatic water drain valve
20