5-30. The oil charging cylinder of the
vapor charging cart has a
capacity of 68 cubic inches and
an operating pressure of 100 psi
at which of the following
temperatures?
1. 120°F
2. 125°F
3. 130°F
4. 135°F
5-31. Refrigerant cylinders should
never be filled to more than what
percent of their capacity?
1.
65 percent
2.
75 percent
3.
85 percent
4.
95 percent
Learning Objective:
Indentify components and
conditions pf the ECS for
the cockpit, cabin area,
and the nose avionics
compartment of the SH-60B
helicopter.
5-32. The SH-60B helicopter cabin
cockpit and nose bay environ-
ments are controlled by the ECS,
which provides both heating and
air conditioning within what
temperature range?
1. 2° to 71°C
2. 2° to 73°C
3. 3° to 72°C
4. 5° to 70°C
5-33. Bleed air is applied to the air-
cycle machine (ACM) through a
modulating valve which functions
in what capacity?
1. As an on/off valve and
pressure relief valve
2. As an on/off valve and
temperature control valve
3. As a pressure regulator and
relief valve
4. AS an on/off valve and
pressure regulator
5-34. With ECS selected ON (from engine
source), maximum torque available
is reduced by what percent?
1.
1.5
2.
2.5
3.
3.5
4.
4.5
5-35.
In an overpressure condition, the
overpressure switch will cause
which of the following actions?
1.
The ECS HI PRESS advisory
panel light to come on
2.
The modulating valve to close
3.
System shutdown only
4.
None of the above
5-36.
(Refer to figure 3-19 and
supporting material in the text.)
The ECS control panel contains a
three-position toggle switch to
control the ECS operating modes.
What are the three settings for
this toggle switch?
1.
OFF, ON, and MAN
2.
OFF, AUTO, and MAN
3.
OFF, ON, and RAM AIR
4.
OFF, AUTO, and RAM AIR
5-37.
The ECS will automatically shut
down under which of the following
conditions?
1.
2.
3.
4.
Engine contingency power is
selected with the
contingency-power switch
(CNTGY PWR) on either
collective stick
In any position of the AIR
SOURCE ECS/START switch, when
starting either No. 1 or No.
2 engine
Both 1 and 2 above
None of the above
5-38.
Fan control is provided by the
mission power (MSU PWR) switch,
and by what other switch?
1.
A 27°C temperature-sensing
switch
2.
A 27°C temperature-sensing
switch located at each fan
outlet
3.
A 25°C temperature-sensing
switch
4.
A 27°C temperature-sensing
switch located at each fan
inlet
Learning Objective:
Recognize the purpose and
function of the aircraft
pressurization system to
include maintenance and
troubleshooting
operations.
34