Chaff Module
You load the chaff module (item 7) with chaff,
decoy flares, jammers, or a mixture of these payloads
and a squib board (item 6). Then, insert it into the
module cavity (item 5). Secure the chaff module in the
cavity by locking the four positive locking latches (item
9). The 120 chaff tubes (item 10) contain the payloads.
Each pod houses two separate modules.
Squib Board
The squib board (item 6) has four layers fastened
and bonded together. The top layer is a thin sheet metal
cover. The second layer is composed of edge spacers to
provide a wire cavity for squib circuits. The remaining
layers are composed of electrical insulating and
fire-retardant
materials.
Two
61-pin
electrical
connectors connect the squib board harness (item 13) to
the intervalometer circuitry. Place the squib board, with
120 Mk 131 or CCU-63/B impulse cartridges inserted,
on top of the chaff module and secure it with eight
captive attachment screws.
Intervalometer
The intervalometer (item 2) is used to control the
burst rate. The intervalometer circuitry responds to the
settings on the pod control indicator or the cockpit
control indicator. The intervalometer contains a
solid-state component electronic timing pulsar to
switch the two automatic stepping switches. The
stepping switches will operate individually for singles
firing or in parallel for doubles firing.
Lanyard Disconnect Switch
The lanyard disconnect switch (item 11) is the main
safety feature preventing cartridge detonation during
chaff loading and ground maintenance. The switch is
normally in the closed position. It is deactivated
(opened) by inserting the lanyard pin in the switch
socket. With the pin inserted, the lanyard disconnect
switch opens the intervalometer circuitry and removes
the electrical path to the squib board circuits.
Access Plates
The two access plates (item 12) provide access to
the pod electrical connectors.
Pod Control Indicator
The pod control indicator (fig. 10-25) is located on
the bottom center of the pod. It provides a means of
selecting the burst rate and firing sequence. The
controls are preset before flight to meet expected
mission requirements. Table 10-1 lists the eight
10-22
Figure 10-25.Pod control indicator.
SINGLE-DOUBLE
POSITION
BURST RATE POSITION
TOTAL TIME TO
EMPTY
SINGLE
SINGLE
SINGLE
SINGLE
DOUBLE
DOUBLE
DOUBLE
DOUBLE
1/4 SEC (0.25 Sec)
1/2 SEC (0.5 Sec)
1 SEC
2 SEC
1/4 SEC (0.25 Sec)
1/2 SEC (0.5 Sec)
1 SEC
2 SEC
1 minute
2 minutes
4 minutes
8 minutes
30 seconds
1 minute
2 minutes
4 minutes
Table 10-1.Firing Time and Sequence