b. Position MXU-651/B wings so that latch
mechanism is at 12 o'clock in line with the
bomb lugs.
NOTE: Mk 3 arming wire installation for the
GBU-12 and GBU-16 is the same as for GP
bombs, discussed earlier in this chapter.
6.
Remove safety cotter pin from pullout pin.
7.
Keep arming wire taut while pressing the wing
against
the
bomb
body.
Hand
tighten
setscrews.
8.
Torque setscrews to the required torque.
13-17
Figure 13-17.GBU-12/16/10 wing assembly installation.