9. Remove the access cover, ensure that no kinks
are in the arming wire, and that the wire is not
looped around pull-out pin (fig. 13-18).
10.
Secure access cover.
11.
Wrap arming wire around wing assembly.
12.
Mark wing assembly with type of fuze and date
installed, fuze safety pin removed, and current
date and QA initials.
Forward Adapter Assembly Installation
Install forward adapter assembly (fig. 13-19) on
nose of bomb as follows:
1.
Place O-ring on external threads of retainer
bolt.
2.
Install retainer bolt into nose fuze well (fig.
13-20).
3.
Torque retainer bolt to specified torque by
using wrench adapter (fig. 13-20).
4.
Apply specified torque to setscrew in nose fuze
well (fig. 13-20).
5.
Install fuze seal nut in retainer bolt and tighten
(fig. 13-20) setscrew or install MXU-735 and
tighten to required torque (fig 13-19).
6.
Place open end of forward adapter over nose
bomb body. Align arming wire guide with
suspension lugs on bomb body.
7.
Install clamp ring onto retainer bolt (fig.
13-21). Back out setscrew to prevent assembly
interference.
8.
Torque clamp ring to specified torque.
9.
Verify arming wire guide is aligned with
suspension lugs of bomb body.
13-18
Figure 13-18.Arming wire installation.
MXU-735
(ALTERNATE)
SETSCREW
SETSCREW
CLAMP
RING
BOLT (4)
FORWARD ADAPTER
RELEASE CABLE (3)
O-RING
SETSCREW
RETAINER
BOLT
FUZE
RETAINING
NUT
FUZE
SEAL
NUT
AOf1319