CHAPTER 3
ANSWERS TO REVIEW QUESTIONS
A3-1. Pneumatic pressure from externally serviced reservoirs
A3-2. Reference mark
A3-3. Acrylic
A3-4. Hydraulically
A3-5. It regulates the speed of the canopy-lock pneumatic actuator during locking and
unlocking of the canopy.
A3-6. 225 psi
A3-7. (a) 225 cubic inch, (b) 3,000 psi
A3-8. Reservoir relief valve
A3-9. Downstream of the auxiliary pneumatic reservoir
A3-10. Three-port pressure operated
A3-11. Five
A3-12. Hold
A3-13. 10 seconds
A3-14. Auxiliary opening
A3-15. To provide an airtight seal between the canopy assembly and the aircraft
A3-16. 25 5 psi
A3-17. Service air heat exchanger
A3-18. Check valve
A3-19. XSMDC, FCDC, and SMDC
A3-20. Internal canopy initiators
A3-23. SMDC
A3-24. One-way explosive transfers
A3-25. Ground emergency conditions
A3-26. Provides a means of escape from the aircraft for crewmembers after ditching or
after a wheels-up landing by initiation of explosive charges to blow out windows
and hatches
A3-27. False
A3-28. 10-foot lanyard
A3-29. Three
3-15