1-23.
When preparing the differential pressure
gage correction card, you must connect
the precision 0 to 100 in. H20
low-pressure gage to which of the
following components?
1.
Pressure gage calibration kit
2.
Relief valve
3.
Flowmeter 125-250 mm
4.
Bell jar bottom coupling
1-24.
When you are preparing the differential
pressure gage correction card, what
initial pressure is used to compare the
readings on the 0 to 100 in. H20
low-pressure gage and the differential
pressure gage?
1.
25 in. H20
2.
50 in. H20
3.
100 in. H20
1-25.
To complete the differential pressure
qage correction card after making the
correction for 100 in. H20, you must drop
the pressure in what increments?
1.
10 in. H20
2.
20 in. H20
3.
25 in. H20
1-26.
To prepare the test pressure gage
correction card, you must connect the
bell jar bottom coupling to which of
the following precision gages?
1.
0 to 100 psig
2.
0 to 200 psig
3.
0 to 500 psig
4.
Differential pressure gage
1-27.
The pointer of the low-pressure test gage
can be adjusted by which of the following
methods?
1.
Turning the adjustment screw on the
back of the gage
2.
Turning the adjustment screw on the
front of the gage
3.
Opening the oxygen supply valve
4.
Closing the oxygen supply valve
1-28.
When preparing the correction card for
the low-pressure test gage, you must use
the bleed valve to reduce the pressure
indicated on the precision-O-to-200-psig
pressure test gage. What maximum
increments are used to reduce the
indicated pressure?
1.
2 psig
2.
5 psig
3.
25 psig
4.
50 psig
1-29.
When preparing the correction card for
the low-pressure gage, you make your
first correction reading at 14 psig.
How many other readings are required?
1.
Five
2. Two
3.
Six
4.
Four
1-30.
When preparing the linear flow element
correction cards, you should start with
which of the following 1pm flow elements?
1.
0 to 50
2.
0 to 100
3.
0 to 150
4.
0 to 200
1-31.
By setting the oxygen supply valve V-6 to
150 1pm on the 500- to 750-mm calibration
kit flow element, the flow, in. H20, will
be displayed on which of the following
flowmeter indicators?
1. PG-1
2. PG-2
3. PG-3
4. PG-4
1-32.
Upon completion of any maintenance action
on the 59A120 test stand, you must
complete which of the following forms?
1.
Ground Support Equipment Subcustody
and Periodic Maintenance Record
(OPNAV 4790/50)
2.
Ground Support Equipment Custody and
Maintenance Record (OPNAV 4790/51)
3.
both 1 and 2 above
4.
VIDS/MAF
1-33.
Which of the following manuals contains
information on the 59A120 test stand?
1.
NAVAIR 17-15BC-20
2.
NAVAIR 17-18BC-30
3.
NAVAIR 13-5-501
4.
OPNAV 4790.2A
1-34.
WhO has the responsibility to repair a
defective flow element that consistently
reads low?
1.
Only personnel of the PR rate
2.
Only E-6 and above personnel of the
PR rate
3.
Local AIMD personnel assisted by the
calibration team
3