5-24.
If the hydraulic fluid test filter
displays a rust color, what color
contamination standard should you
use for comparison?
1.
Tan
2.
Rust
3. Gray
4.
Silica
5-25.
An electronic particle count
analysis of hydraulic fluid will
NOT be affected by particles
smaller than what size?
1.
50 microns
2.
25 microns
3.
15 microns
4.
5 microns
5-26.
The halogen leak detector is
powered by what source of energy?
1. Solar
2.
Battery
3.
110 volts ac
4.
220 volts ac
5-27.
When you circulate contaminated
fluid through the filters in an
aircraft and a portable hydraulic
test stand, you are using which of
the following decontamination
methods?
1.
Purging
2.
Flushing
3.
Purifying
4.
Recirculation cleaning
5-28.
Unless specified by other
publications, a hydraulic system
undergoing the recirculation
cleaning process should be cycled a
minimum of how many complete
cycles?
1. 5 cycles
2.
10 cycles
3.
15 cycles
4.
25 cycles
5-29.
You should perform a hydraulic
fluid patch test from what system
component to determine when system
flushing is complete?
1. System reservoir fluid
2.
System return line fluid
3.
System pressure line fluid
4.
Test stand reservoir fluid
5-30.
Test stands used for hydraulic
system flushing must have an
internal reservoir that holds what
minimum number of gallons?
1.
10 gal
2.
14 gal
3.
16 gal
4.
20 gal
5-31.
Which of the following authorities
is required to recommend and
supervise an aircraft hydraulic
system purging?
1. The commanding officer
2.
The maintenance officer
3.
The cognizant engineering
activity
4.
The cognizant functional wing
commander
5-32.
When a hydraulic system is
purified, the fluid going to the
purification tower is first
filtered by what size filter?
1. 5 micron
2.
15 micron
3.
3 micron
4.
25 micron
5-33.
When considering maintenance man-
hours and material requirements,
what method of hydraulic system
decontamination is the most
effective?
1.
Purging
2.
Flushing
3.
Purifying
4.
Recirculation cleaning
5-34.
What fire-resistant type of
hydraulic fluid was developed to
replace MIL-H-5606?
1. MIL-H-6083
2.
MIL-H-83282
3.
MIL-H-46170
4.
MIL-H-81019
5-35.
Which of the following types of
hydraulic fluids is used in
extremely low temperatures?
1. MIL-H-5606
2.
MIL-H-46170
3.
MIL-H-81019
4.
MIL-H-83282
5-36.
When servicing hydraulic systems,
you should use what type of
filtration?
1.
3-micron (absolute)
2.
3-micron (nominal)
3.
5-micron (absolute)
4.
5-micron (nominal)
24