Figure 7-7.--A2 panel--Continued.
BLEED AIR.--Under the heading BLEED
preset alarm limit. The second LED is labeled
FLOW LOW. It illuminates amber when the
AIR, there is an LED indicator and four push
respective propeller hydraulic oil flow rate is at
buttons for each (port and starboard) bleed
air system. The LEDs, labeled PRESS LOW,
or below the preset alarm limit.
illuminate amber if the respective bleed air header
Mounted vertically and below the two LEDs
pressure falls below its alarm set point. The first
are the four push buttons under the heading
two push buttons are for the PRAIRIE AIR valve.
ELEC PUMP. The first push button is labeled
They are labeled ON and OFF, respectively, and
MANUAL. When depressed, it illuminates amber
to indicate the operator has manual control of the
illuminate green to indicate the status of or
operator's command to the valve. The last two
electric LO pump. The second push button is
push buttons are for the HULL MASKER valves.
labeled AUTO. When depressed, it illuminates
green to indicate the pump is in the automatic
They are labeled ON and OFF, respectively, and
illuminate green to indicate the status of or
mode. The third push button is located under
operator's command to the valve.
the AUTO push button and is labeled ON. It
illuminates green to indicate the pump status or
operator command to the pump. This push
button is active in the MANUAL or AUTO
control mode. The last push button is labeled
OFF. It illuminates green to indicate the pump
status or operator command to the pump. This
push button is also active in the MANUAL or
AUTO control mode.
indicators and four push buttons for each (port
and starboard) propeller hydraulic system.
The two LEDs are located under the heading
PORT(STBD). The first LED, labeled FLOW
HIGH, illuminates amber when the respective
propeller hydraulic oil flow rate is at or above the
7-15